1.3 Workcell Layout
1.3 Workcell Layout
The following figure shows a simple workcell layout with a user-supplied safety barrier and E-
Stops provided by the Front Panel and optional T20 pendant.
Front Panel
T20 P
endant -
Optional
PC running
PLC Programming
Software
Safety Barrier
Restricted Area
Inside Safety
Barrier
200-240 VAC
T
ypical Workcell Layout
Adept ePLC
Cobra Robot
24 VDC
XUSR
Programmable Logic
Controller (PLC)
User-Supplied
Components
STOP
R
Figure 1-1. Typical Workcell Layout
1.4 Installing the Robot
NOTE:Do not move the robot’s outer arm from the shipping position, as shown.
Support the robot by the eyebolt on the top of the inner link before removing the shipping bolts
from the pallet. This will prevent the robot from tipping over. See the following figure.
Adept Cobra ePLC600/800 Quick Setup Guide, Rev C
Page 4 of 16
Comentarios a estos manuales